DC input |
Input format | DC +/DC-and PE |
voltage range | 300Vdc ~ 825Vdc | |
Not operating to withstand maximum static voltage | 900Vdc | |
rated voltage | 700Vdc | |
Maximum current | 50A | |
Standby damage | < 14W @ 700 Vdc with normal sandby mode
< 4W @ 700 Vdc with super sandby mode |
|
MPPT Mode 1 |
MPPT operating voltage range | 300Vdc ~ 740Vdc |
MPPT Full Load Voltage Range | 650Vdc ~ 740Vdc | |
MPPT starting voltage | 375Vdc | |
MPPT Maximum Input Current | ≤ 50A (@ 650Vdc) | |
MPPT efficiency | > 99.5% (MPP ≥ 5000W) | |
Input parallel MPPT tracking function | Supports monitoring and setting, power-down mode saving, and up to 2 modules are connected in parallel | |
DC output |
voltage range | 150Vdc ~ 1000Vdc |
Current range | 0 ~ 100A (current limiting point can be set) | |
rated current | 30A (required to set current limiting point) | |
Voltage stabilization accuracy | < ± 0. 5% (150 ~ 1000V, 0 ~ 20MHz) | |
Steady current accuracy | ≤ ± 1% (output load 20% ~ 100% rated range) | |
adjustment rate |
load regulation rate | ≤±0.5% |
Source adjustment rate | ≤ ± 0. 1% (test range is 650V ~ 825V) | |
Start overshoot | ≤±3% | |
Voltage ripple |
Voltage ripple factor | ≤ 1% (150 ~ 1000V, 0 ~ 20MHz) |
EMC Metrics |
immunity | Class B, refer to IEC61851-21-2 |
Conducted emission | Class B, refer to IEC61851-21-2 | |
Radiation emission | Class B, refer to IEC61851-21-2 |